Sterilisers
Medicine has the goal of protecting and saving lives. Therefore, disinfection of receptacles and instruments is not enough. The setpoint-dependent programme resume function SetpointWAIT of Memmert hot air sterilisers guarantees precise sterilisation times and the complete killing off of even the most resistant microorganisms. The appliances comply with all relevant national and international standards and requirements for medical devices and can be validated without problems.
- Adjustment of pre-heated fresh air admixture by air flap control in 10 % steps.
- Adaptive multifunctional digital PID-microprocessor controller with high-definition TFT-colour display.
- Self-diagnostics for fault analysis.
- One Pt100 sensor DIN class A.
- Digital backwards counter with target time setting, adjustable from 1 minute to 99 days.
- Parameters adjustable on ControlCOCKPIT: temperature (Celsius or Fahrenheit), air flap position, programme time, time zones, summertime/wintertime.
- SetpointWAIT function - the process time does not start until the set temperature is reached.
- Resolution of display for setpoint values 0.1 °C up to 99.9 °C, 0.5 °C from 100 °C and for actual values 0.1 °C (LED).
- Programme stored in case of power failure.
- Delivered with works calibration certificate for +160 °C.
- Adjustable electronic overtemperature monitor and mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20 °C above nominal temperature.
- Fully insulated stainless steel door with 2-point locking.
- Easy-to-clean interior, made of stainless steel with large-area heating of four sides.
Model/Parameter | 30 | 55 | 75 | 110 | 160 | 260 | 450 | 750 | |
Volume, l | 32 | 53 | 74 | 108 | 161 | 256 | 449 | 749 | |
Interior width, mm | 400 | 400 | 400 | 560 | 560 | 640 | 1040 | 1040 | |
Interior height, mm | 320 | 400 | 560 | 480 | 720 | 800 | 720 | 1200 | |
Interior depth, mm | 250 | 330 | 330 | 400 | 400 | 500 | 600 | 600 | |
Max. number of shelves | 3 | 4 | 6 | 5 | 8 | 9 | 8 | 14 | |
Max. loading per shelf, kg | 20 | 20 | 20 | 20 | 20 | 20 | 30 | 30 | |
Max. loading of chamber, kg | 60 | 80 | 120 | 175 | 210 | 300 | 300 | 300 | |
Exterior width, mm | 585 | 585 | 585 | 745 | 745 | 824 | 1224 | 1224 | |
Exterior height, mm | 704 | 784 | 944 | 864 | 1104 | 1183 | 1247 | 1720 | |
Exterior depth, mm | 434 | 514 | 514 | 584 | 584 | 684 | 784 | 784 | |
Electrical load at 230 V, 50/60 Hz, W | 1600 | 2000 | 2500 | 2800 | 3200 | 3400 | |||
Electrical load at 400 V, 50/60 Hz, W | 5800 | 7000 | |||||||
Net weight, kg | 46 | 57 | 66 | 74 | 96 | 110 | 161 | 217 |